Yueqing Leyu Electric Automation Co., Ltd.
Products
Contact Us
  • Contact Person : Mr. Chan Rain
  • Company Name : Yueqing Leyu Electric Automation Co., Ltd.
  • Tel : 86-577-62998958
  • Fax : 86-577-62981651
  • Address : Zhejiang,WENZHOU,Xiangnandoang baixiang yueqing
  • Country/Region : China
  • Zip : 325603

High quality 230v 110v transformers

High quality 230v 110v transformers
Product Detailed
Related Categories:Switching Power Supply
1.High quality 230v 110v transformers 2.CE ROHS approved 3.Provide customized specification 4.High efficiency

25W Single Output Switching Power Supply      NES-25 series

Features :

Universal AC input / Full range

Protections: Short circuit / Overload / Over voltage

Cooling by free air convection

100% full load burn-in test

1 year warranty

SPECIFICATION

OUTPUT

Model

NES-25-5

NES-25-12

NES-25-15

NES-25-24

NES-25-48

DC Voltage

5V

12V

15V

24V

48V

Rated Current

5A

2.1A

1.7A

1.1A

0.57A

Current Range

0 ~ 5A

0 ~ 2.1A

0 ~ 1.7A

0 ~ 1.1A

0 ~ 0.57A

Rated Power

25W

25.2W

25.5W

26.4W

27.36W

Ripple & Noise

80mVp-p

120mVp-p

150mVp-p

200mVp-p

240mVp-p

Voltage Adj. Range

4.75~5.5V

10.8~13.2V

13.5~16.5V

21.6~26.4V

43.2~52.8V

Voltage Tolerance

±2.0%

±1.0%

±1.0%

±1.0%

±1.0%

Line Regulation

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Load Regulation

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Setup, Rise Time

500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load

Hold Up Time

50ms/230VAC  10ms/115VAC at full load

INPUT

Voltage Range

85 ~ 264VAC   120 ~ 370VDC

Frequency Range

47 ~ 63Hz

Efficiency

78%

83%

84%

86%

86%

AC Current

0.55A/115VAC 0.35A/230VAC

Inrush Current

Cold Start 45A

Leakage Current

<2mA / 240VAC

PROTECTION

Over Load

110 ~ 150% rated output power

Protection type: Hiccup mode, recovers automatically after fault condition is removed

Over Voltage

5.75~6.75V

13.8~16.2V

17.25~20.25V

27.6~32.4V

55.2~64.8V

Protection type: Shut down o/p voltage, re-power on to recover

ENVIRONMENT

Working Temp.

-20 ~ +60°C (Refer to “Derating Curve”)

Working Humidity

20 ~ 90% RH non-condensing

Storage Temp., Humidity

-40 ~ +85°C, 10 ~ 95% RH

Temp. Coefficient

±0.03%/°C (0 ~ 45°C)

Vibration

10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

SAFETY & EMC

Safety Standards

UL60950-1, CB(IEC60950-1),CCC GB4943 approved

Withstand Voltage

I/P-O/P:3KVAC   I/P-FG:1.5KVAC O/P-FG:0.5KVAC

Isolation Resistance

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C / 70% RH

EMC Emission

Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3

EMC Immunity

Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, EN55024, EN61000-6-1, light industry level, criteria A

OTHERS

Dimension

99*82*35mm (L*W*H)

Weight

0.3Kg

Packing

45pcs/14.5Kg/0.66CUFT

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. Line regulation is measured from low line to high line at rated load.

High quality 230v 110v transformers